Wednesday, May 07, 2008
DataProtecter 6 has a problem
We're moving our BackupExec environment to HP DataProtector. Don't ask why, it made sense at the time.
Once of the niiiice things about DP is what's called, "Enhanced Incremental Backup". This is a de-duplication strategy, that only backs up files that have changed, and only stores the changed blocks. From these incremental backups you can construct synthetic full backups, which are just pointer databases to the blocks for that specified point-in-time. In theory, you only need to do one full backup, keep that backup forever, do enhanced incrementals, then periodically construct synthetic full backups.
We've been using it for our BlackBoard content store. That's around... 250GB of file store. Rather than keep 5 full 275GB backup files for the duration of the backup rotation, I keep 2 and construct synthetic fulls for the other 3. In theory I could just go with 1, but I'm paranoid :). This greatly reduces the amount of disk-space the backups consume.
Unfortunately, there is a problem with how DP does this. The problem rests on the client side of it. In the "$InstallDir$\OmniBack\enhincrdb" directory it constructs a file hive. An extensive file hive. In this hive it keeps track of file state data for all the files backed up on that server. This hive is constructed as follows:
The last real full backup I took of the content store backed up just under 1.7 million objects (objects = directory entries in NetWare, or IIRC inodes in unix-land). Yet the enhincrdb hive had 2.7 million objects. Why the difference? I'm not sure, but I suspect it was keeping state data for 1 million objects that no longer were present in the backup. I have trouble believing that we managed to churn over 60% of the objects in the store in the time I have backups, so I further suspect that it isn't cleaning out state data from files that no longer have a presence in the backup system.
DataProtector doesn't support Enhanced Incrementals for NetWare servers, only Windows and possibly Linux. Due to how this is designed, were it to support NetWare it would create absolutely massive directory structures on my SYS: volumes. The FACSHARE volume has about 1.3TB of data in it, in about 3.3 directory entries. The average FacStaff User volume (we have 3) has about 1.3 million, and the average Student User volume has about 2.4 million. Due to how our data works, our Student user volumes have a high churn rate due to students coming and going. If FACSHARE were to share a cluster node with one Student user volume and one FacStaff user volume, they have a combined directory-entry count of 7.0 million directory entries. This would generate, at first, a \enhincrdb directory with 7.0 million files. Given our regular churn rate, within a year it could easily be over 9.0 million.
When you move a volume to another cluster node, it will create a hive for that volume in the \enhincrdb directory tree. We're seeing this on the BlackBoard Content cluster. So given some volumes moving around, and it is quite conceivable that each cluster node will have each cluster volume represented in its own \enhincrdb directory. Which will mean over 15 million directory-entries parked there on each SYS volume, steadily increasing as time goes on taking who knows how much space.
And as anyone who has EVER had to do a consistency check of a volume that size knows (be it vrepair, chkdsk, fsck,or nss /poolrebuild), it takes a whopper of a long time when you get a lot of objects on a file-system. The old Traditional File System on NetWare could only support 16 million directory entries, and DP would push me right up to that limit. Thank heavens NSS can support w-a-y more then that. You better hope that the file-system that the \enhincrdb hive is on never has any problems.
But, Enhanced Incrementals only apply to Windows so I don't have to worry about that. However.... if they really do support Linux (and I think they do), then when I migrate the cluster to OES2 next year this could become a very real problem for me.
DataProtector's "Enhanced Incremental Backup" feature is not designed for the size of file-store we deal with. For backing up the C: drive of application servers or the inetpub directory of IIS servers, it would be just fine. But for file-servers? Good gravy, no! Unfortunately, those are the servers in most need of de-dup technology.
Once of the niiiice things about DP is what's called, "Enhanced Incremental Backup". This is a de-duplication strategy, that only backs up files that have changed, and only stores the changed blocks. From these incremental backups you can construct synthetic full backups, which are just pointer databases to the blocks for that specified point-in-time. In theory, you only need to do one full backup, keep that backup forever, do enhanced incrementals, then periodically construct synthetic full backups.
We've been using it for our BlackBoard content store. That's around... 250GB of file store. Rather than keep 5 full 275GB backup files for the duration of the backup rotation, I keep 2 and construct synthetic fulls for the other 3. In theory I could just go with 1, but I'm paranoid :). This greatly reduces the amount of disk-space the backups consume.
Unfortunately, there is a problem with how DP does this. The problem rests on the client side of it. In the "$InstallDir$\OmniBack\enhincrdb" directory it constructs a file hive. An extensive file hive. In this hive it keeps track of file state data for all the files backed up on that server. This hive is constructed as follows:
- The first level is the mount point. Example: enhincrdb\F\
- The 2nd level are directories named 00-FF which contain the file state data itself
The last real full backup I took of the content store backed up just under 1.7 million objects (objects = directory entries in NetWare, or IIRC inodes in unix-land). Yet the enhincrdb hive had 2.7 million objects. Why the difference? I'm not sure, but I suspect it was keeping state data for 1 million objects that no longer were present in the backup. I have trouble believing that we managed to churn over 60% of the objects in the store in the time I have backups, so I further suspect that it isn't cleaning out state data from files that no longer have a presence in the backup system.
DataProtector doesn't support Enhanced Incrementals for NetWare servers, only Windows and possibly Linux. Due to how this is designed, were it to support NetWare it would create absolutely massive directory structures on my SYS: volumes. The FACSHARE volume has about 1.3TB of data in it, in about 3.3 directory entries. The average FacStaff User volume (we have 3) has about 1.3 million, and the average Student User volume has about 2.4 million. Due to how our data works, our Student user volumes have a high churn rate due to students coming and going. If FACSHARE were to share a cluster node with one Student user volume and one FacStaff user volume, they have a combined directory-entry count of 7.0 million directory entries. This would generate, at first, a \enhincrdb directory with 7.0 million files. Given our regular churn rate, within a year it could easily be over 9.0 million.
When you move a volume to another cluster node, it will create a hive for that volume in the \enhincrdb directory tree. We're seeing this on the BlackBoard Content cluster. So given some volumes moving around, and it is quite conceivable that each cluster node will have each cluster volume represented in its own \enhincrdb directory. Which will mean over 15 million directory-entries parked there on each SYS volume, steadily increasing as time goes on taking who knows how much space.
And as anyone who has EVER had to do a consistency check of a volume that size knows (be it vrepair, chkdsk, fsck,or nss /poolrebuild), it takes a whopper of a long time when you get a lot of objects on a file-system. The old Traditional File System on NetWare could only support 16 million directory entries, and DP would push me right up to that limit. Thank heavens NSS can support w-a-y more then that. You better hope that the file-system that the \enhincrdb hive is on never has any problems.
But, Enhanced Incrementals only apply to Windows so I don't have to worry about that. However.... if they really do support Linux (and I think they do), then when I migrate the cluster to OES2 next year this could become a very real problem for me.
DataProtector's "Enhanced Incremental Backup" feature is not designed for the size of file-store we deal with. For backing up the C: drive of application servers or the inetpub directory of IIS servers, it would be just fine. But for file-servers? Good gravy, no! Unfortunately, those are the servers in most need of de-dup technology.
Thursday, March 06, 2008
More HP annoyances
They've recently revised their alert emails to be even more badly formatted. The below slug of text contains a critical alert. Somewhere.
This is a plain-text email, no HTML->Plain formatting weirdness. It COMES this glommed together. Time to send a cranky-gram.
Your alerts
Document: Customer Advisory; Link:
http://alerts.hp.com/r?2.1.3KT.2ZR.xl4lg.C0m3Bi..T.DSeQ.1Lki.DKEbf000 Priority:
Critical; Products: All-in-One Storage Systems,Disk-to-disk Backup,HP Integrity
Entry-level Servers,HP Integrity High-end Servers,HP Integrity Mid-range Servers;
OS: not applicable; Release Date: Feb 26 2008; Description: Advisory: (Revision)
FIRMWARE UPGRADE or WORKAROUND REQUIRED to Prevent Rare Scenario of Potential
Logical Drive Failure on HP Smart Array Controller Attached to Multiple Drive
Arrays if Drive Failure or Incorrect Drive Replacement Occurs After Power Loss
(c01232270) Document: Customer Advisory; Link:
http://alerts.hp.com/r?2.1.3KT.2ZR.xl4lg.C0m3Bi..T.DTgW.1Lki.ccEcI000 Priority:
Recommended; Products: HP ProLiant BL Server Blades,HP ProLiant DL Servers,HP
ProLiant ML Servers,MSA Disk Arrays,Server Controllers; OS: not applicable; Release
Date: Feb 28 2008; Description: Advisory: FIRMWARE UPGRADE RECOMMENDED for Certain
HP Smart Array Controllers to Avoid False SAS and SATA Hard Drive (c01382041)
Document: Customer Advisory; Link:
http://alerts.hp.com/r?2.1.3KT.2ZR.xl4lg.C0m3Bi..T.DTf8.1Lki.DeBcEbI0 Priority:
Routine; Products: HP ProLiant BL Server Blades,HP ProLiant DL Servers,HP ProLiant
ML Servers,HP ProLiant Packaged Cluster Servers,Server/Storage Infrastructure
Management Software; OS: not applicable; Release Date: Feb 20 2008; Description:
Advisory: HP Systems Insight Manager (HP SIM) Running in an Environment with a
Large Number of WBEM Managed Nodes May Experience Task Page Interface Slowdown or
Out of Memory Errors (c01371984) Document: Customer Advisory; Link:
http://alerts.hp.com/r?2.1.3KT.2ZR.xl4lg.C0m3Bi..T.DTgo.1Lki.DAMEdA00 Priority:
Routine; Products: HP ProLiant BL Server Blades,Server Management Software; OS: not
applicable; Release Date: Feb 28 2008; Description: Advisory: Virtual Connect
Enterprise Manager (VCEM) 1.0 May Not Be Able To Add Virtual Connect (VC) Domains
to a Virtual Connect Domain Group After Updating the VC Domain Group on a ProLiant
Server (c01382035) Document: Customer Advisory; Link:
http://alerts.hp.com/r?2.1.3KT.2ZR.xl4lg.C0m3Bi..T.DTgi.1Lki.CPQEca00 Priority:
Routine; Products: HP ProLiant BL Server Blades,HP ProLiant DL Servers,HP ProLiant
Packaged Cluster Servers; OS: not applicable; Release Date: Feb 28 2008;
Description: Advisory: ProLiant Essentials Virtual Machine Manager (VMM) Displays
Incorrect VMM Warning Message on FireFox Browser for ActiveX Controls (c01382044)
Document: Customer Advisory; Link:
http://alerts.hp.com/r?2.1.3KT.2ZR.xl4lg.C0m3Bi..T.DTgQ.1Lki.MAEcC000 Priority:
Routine; Products: HP ProLiant BL Server Blades,HP ProLiant DL Servers,HP ProLiant
ML Servers,HP ProLiant Packaged Cluster Servers; OS: not applicable; Release Date:
Feb 28 2008; Description: Advisory: (c01382042) Document: Customer Advisory;
Link: http://alerts.hp.com/r?2.1.3KT.2ZR.xl4lg.C0m3Bi..T.DTgg.1Lki.CJcEcY00
Priority: Routine; Products: HP ProLiant DL Servers,HP ProLiant ML Servers,HP
ProLiant Packaged Cluster Servers,Server Network Interface Cards; OS: not
applicable; Release Date: Feb 28 2008; Description: Advisory: Novell NetWare
Teaming Driver (QASM.LAN) May Fail to Load After Upgrading to ProLiant Support Pack
for Novell NetWare 7.80 (or later) (c01382039) Document: Customer Advisory; Link:
http://alerts.hp.com/r?2.1.3KT.2ZR.xl4lg.C0m3Bi..T.DTgU.1Lki.XIEcG000 Priority:
Routine; Products: All-in-One Storage Systems,HP Integrity Entry-level Servers,HP
Integrity High-end Servers,HP Integrity Mid-range Servers,HP ProLiant BL Server
Blades; OS: not applicable; Release Date: Feb 28 2008; Description: Advisory:
(Revision) HP ProLiant Smart Array SAS/SATA Event Notification Service Version
6.4.0.xx Does Not Log All Events to the Windows Registry (c01177411) Document:
Customer Advisory; Link:
http://alerts.hp.com/r?2.1.3KT.2ZR.xl4lg.C0m3Bi..T.DTgk.1Lki.CVEEcc00 Priority:
Routine; Products: HP ProLiant BL Server Blades,HP ProLiant DL Servers,HP ProLiant
ML Servers,HP ProLiant Packaged Cluster Servers,ProLiant Essentials Software; OS:
not applicable; Release Date: Feb 28 2008; Description: Advisory: SmartStart
Scripting Toolkit Reboot Utility May Not Respond Or May Display a Segmentation
Fault Error On a ProLiant Server Running SUSE LINUX Enterprise Server 10 Service
Pack 1 (SP1) (c01382031) Document: Customer Notice; Link:
http://alerts.hp.com/r?2.1.3KT.2ZR.xl4lg.C0m3Bi..T.DTh2.1Lki.DdWYEbE0 Priority:
Routine; Products: HP ProLiant BL Server Blades,HP ProLiant DL Servers,HP ProLiant
ML Servers; OS: not applicable; Release Date: Feb 28 2008; Description: Notice:
Linux System Health Application and Insight Management Agents (hpasm),
Lights-Out-Driver and Agents (hprsm), and NIC Agents (cmanic) Are Now Delivered as
a Single rpm Package for all Supported HP ProLiant Linux Servers (c01382040)
Document: Customer Advisory; Link:
http://alerts.hp.com/r?2.1.3KT.2ZR.xl4lg.C0m3Bi..T.DU7I.1Lki.DbNQEaL0 Priority:
Routine; Products: HP ProLiant BL Server Blades,HP ProLiant DL Servers,HP ProLiant
ML Servers,HP ProLiant Packaged Cluster Servers; OS: not applicable; Release Date:
Feb 28 2008; Description: Advisory: Virtual Machine Manager (VMM) 3.1 May Cause a
(c01383032)
This is a plain-text email, no HTML->Plain formatting weirdness. It COMES this glommed together. Time to send a cranky-gram.
Monday, January 07, 2008
I/O starvation on NetWare, another update
I've spoken before about my latency problems on the MSA1500cs. Since my last update I've spoken with Novell at length. Their own back-line HP people were thinking firmware issues to, and recommended I open another case with HP support. And if HP again tries to lay the blame on NetWare, to point their techs at the NetWare backline tech. Who will then have a talk about why exactly it is that NetWare isn't the problem in this case.
This time when I opened the case I mentioned that we see performance problems on the backup-to-disk server, which is Windows. Which is true, when the problem occurs B2D speeds drop through the floor; last Friday a 525GB backup that normally completes in 6 hours took about 50 hours. Since I'm seeing problems on more than one operating system, clearly this is a problem with the storage device.
The first line tech agreed, and escalated. The 2nd line tech said (paraphrased):
That may be where we have to go with this. Unfortunately, I don't think we have 16TB of disk-drives available to fully mirror the cluster. That'll be a significant expense. So, I think we have some rethinking to do regarding what we use this device for.
This time when I opened the case I mentioned that we see performance problems on the backup-to-disk server, which is Windows. Which is true, when the problem occurs B2D speeds drop through the floor; last Friday a 525GB backup that normally completes in 6 hours took about 50 hours. Since I'm seeing problems on more than one operating system, clearly this is a problem with the storage device.
The first line tech agreed, and escalated. The 2nd line tech said (paraphrased):
I'm seeing a lot of parity RAID LUNs out there. This sort of RAID uses CPU on the MSA1000 controllers, so the results you're seeing are normal for this storage system.Which, if true, puts the onus of putting up with a badly behaved I/O system onto NetWare again. The tech went on to recommend RAID1 for the LUNs that need high performance when doing array operations that disable the internal cache. Which, as far as I can figure, would work. We're not bottlenecking on I/O to the physical disks, the bottleneck is CPU on the MSA1000 controller that's active. Going RAID1 on the LUNs would keep speeds very fast even when doing array operations.
That may be where we have to go with this. Unfortunately, I don't think we have 16TB of disk-drives available to fully mirror the cluster. That'll be a significant expense. So, I think we have some rethinking to do regarding what we use this device for.
Wednesday, November 28, 2007
I/O starvation on NetWare, HP update
Last week I talked about a problem we're having with the HP MSA1500cs and our NetWare cluster. The problem is still there, of course. I've opened cases with both HP and Novell to handle this one. HP because I really thing that such command latencies are a defect, and Novell since they're having starvation issues with clusters.
This morning I got a voice-mail from HP, an update for our case. Greatly summarized:
Especially since I don't think I've made back-line on the Novell case yet. They're involved, but I haven't been referred to a new support engineer yet.
This morning I got a voice-mail from HP, an update for our case. Greatly summarized:
The MSA team has determined that your device is working perfectly, and can find no defects. They've referred the case to the NetWare software team.Or...
Working as designed. Fix your software. Talk to Novell.Which I'm doing. Now to see if I can light a fire on the back-channels, or if we've just made HP admit that these sorts of command latencies are part of the design and need to be engineered around in software. Highly frustrating.
Especially since I don't think I've made back-line on the Novell case yet. They're involved, but I haven't been referred to a new support engineer yet.
Labels: clustering, hp, msa, netware, novell, OES, storage, sysadmin
Monday, November 26, 2007
Adding attachments to an open HP Support case
I don't think this is documented anywhere. But I just learned how to add updates to the HP case-file. Including attachments.
To: support_am@hp.comAny attachments to it will be automatically imported into the case. LOOKING at the case itself is a lot more complicated, and I'm still not sure of the steps. But this should be of use to some of you.
Subject:
CASE_ID_NUM: [case number, such as 36005555555]
MESSAGE: [text]
Wednesday, November 21, 2007
I/O starvation on NetWare
The MSA1500cs we've had for a while has shown a bad habit. It is visible when you connect a serial cable to the management port on the MSA1000 controller, and doing a "show perf" after starting performance tracking. The line in question is "Avg Command Latency:", which is a measure of how long it takes to execute an I/O operation. Under normal circumstances this metric stays between 5-30ms. When things go bad, I've seen it as far as 270ms.
This is a problem with our cluster nodes. Our cluster nodes can seen LUNs on both the MSA1500cs and the EVA3000. The EVA is where the cluster has been housed since it started, and the MSA has taken up two low-I/O-volume volumes to make space on the EVA.
IF the MSA is in the high Avg Command Latency state, and
IF a cluster node is doing a large Write to the MSA (such as a DVD ISO image, or B2D operation),
THEN "Concurrent Disk Requests" in Monitor go north of 1000
This is a dangerous state. If this particular cluster node is housing some higher trafficked volumes, such as FacShare:, the laggy I/O is competing with regular (fast) I/O to the EVA. If this sort of mostly-Read I/O is concurrent with the above heavy Write situation it can cause the cluster node to not write to the Cluster Partition on time and trigger a poison-pill from the Split Brain Detector. In short, the storage heart-beat to the EVA (where the Cluster Partition lives) gets starved out in the face of all the writes to the laggy MSA.
Users definitely noticed when the cluster node was in such a heavy usage state. Writes and Reads took a loooong time on the LUNs hosted on the fast EVA. Our help-desk recorded several "unable to map drive" calls when the nodes were in that state, simply because a drive-mapping involves I/O and the server was too busy to do it in the scant seconds it normally does.
This is sub-optimal. This also doesn't seem to happen on Windows, but I'm not sure of that.
This is something that a very new feature in the Linux kernel could help out, that that's to introduce the concept of 'priority I/O' to the storage stack. I/O with a high priority, such as cluster heart-beats, gets serviced faster than I/O of regular priority. That could prevent SBD abends. Unfortunately, as the NetWare kernel is no longer under development and just under Maintenance, this is not likely to be ported to NetWare.
I/O starvation. This shouldn't happen, but neither should 270ms I/O command latencies.
This is a problem with our cluster nodes. Our cluster nodes can seen LUNs on both the MSA1500cs and the EVA3000. The EVA is where the cluster has been housed since it started, and the MSA has taken up two low-I/O-volume volumes to make space on the EVA.
IF the MSA is in the high Avg Command Latency state, and
IF a cluster node is doing a large Write to the MSA (such as a DVD ISO image, or B2D operation),
THEN "Concurrent Disk Requests" in Monitor go north of 1000
This is a dangerous state. If this particular cluster node is housing some higher trafficked volumes, such as FacShare:, the laggy I/O is competing with regular (fast) I/O to the EVA. If this sort of mostly-Read I/O is concurrent with the above heavy Write situation it can cause the cluster node to not write to the Cluster Partition on time and trigger a poison-pill from the Split Brain Detector. In short, the storage heart-beat to the EVA (where the Cluster Partition lives) gets starved out in the face of all the writes to the laggy MSA.
Users definitely noticed when the cluster node was in such a heavy usage state. Writes and Reads took a loooong time on the LUNs hosted on the fast EVA. Our help-desk recorded several "unable to map drive" calls when the nodes were in that state, simply because a drive-mapping involves I/O and the server was too busy to do it in the scant seconds it normally does.
This is sub-optimal. This also doesn't seem to happen on Windows, but I'm not sure of that.
This is something that a very new feature in the Linux kernel could help out, that that's to introduce the concept of 'priority I/O' to the storage stack. I/O with a high priority, such as cluster heart-beats, gets serviced faster than I/O of regular priority. That could prevent SBD abends. Unfortunately, as the NetWare kernel is no longer under development and just under Maintenance, this is not likely to be ported to NetWare.
I/O starvation. This shouldn't happen, but neither should 270ms I/O command latencies.
Labels: clustering, hp, msa, netware, novell, OES, storage, sysadmin
Tuesday, January 30, 2007
That's odd
HP is advertising their blade systems. I saw an ad for one this weekend on SciFi, and now a banner ad on the front page of economist.com.
This is a system that has zero presence in the home, entirely in datacenters. This is clearly an effort to influence decision makers outside of industry rags like ComputerWorld or NetworkWorld. Yeah, a lot of fellow IT workers I know were sad when Farscape died, so I guess we have a lot of SciFi buffs around.
Hmm.
This is a system that has zero presence in the home, entirely in datacenters. This is clearly an effort to influence decision makers outside of industry rags like ComputerWorld or NetworkWorld. Yeah, a lot of fellow IT workers I know were sad when Farscape died, so I guess we have a lot of SciFi buffs around.
Hmm.
Labels: hp
Wednesday, August 02, 2006
Near heart failure
The thing that caused me to go into near heart failure was one server's misbehaving. I had just finished applying SP5 to one of the WUF servers and it was rebooting. It didn't come right up so I go back and look to see where it might be hung up. Instead what I see is the "Multiple abends occuring, processor halted" screen. Aie!
And it seemed to happen every time on reboot. Some quick looking showed that it happened pretty quickly after NILE.NLM loaded. But due to the nature of the problem, not abend.log was generated for me to know what exactly faulted.
So I drop 'er down to DOS and to a "SERVER -ns -na" and step through the launch process. During this time I noticed that the HP BIOS is expecting a "Windows" server. I thought that was odd, and put it on the list of things to change. I step through boot, and sure enough, during AUTOEXEC.NCF processing it bombs on the multiple-abends-occuring problem. Arrrg. Still don't know what module load caused the problem, though.
So I reboot and change the OS the BIOS is expecting to be NetWare, and reboot. It comes up just peachy.
oooookaaaay.... Didn't know it was that twitchy. Anyway, it is up and running just fine now.
Tags: NetWare, HP
And it seemed to happen every time on reboot. Some quick looking showed that it happened pretty quickly after NILE.NLM loaded. But due to the nature of the problem, not abend.log was generated for me to know what exactly faulted.
So I drop 'er down to DOS and to a "SERVER -ns -na" and step through the launch process. During this time I noticed that the HP BIOS is expecting a "Windows" server. I thought that was odd, and put it on the list of things to change. I step through boot, and sure enough, during AUTOEXEC.NCF processing it bombs on the multiple-abends-occuring problem. Arrrg. Still don't know what module load caused the problem, though.
So I reboot and change the OS the BIOS is expecting to be NetWare, and reboot. It comes up just peachy.
oooookaaaay.... Didn't know it was that twitchy. Anyway, it is up and running just fine now.
Tags: NetWare, HP